Organics Getters

Over time, epoxies and RF absorbers can outgas organics inside a hermetic package after sealing. This type of contamination can lead to poor device performance and ultimately device failure. The Hi-Rel manufactures several getter solutions that address the outgassing of organics as detailed below.

Hi-Rel and Johnson Matthey have been teaming together since 1999 to bring our customers the most robust solutions. Each solution is customized based on application, footprint, RGA analysis and other factors. We work together early in your design process so that whatever organics contaminant issue your electronics face, we customize your exact solutions.

Let us know how we can help.


OfferingForm factorH₂H₂OCO₂O₂OrganicsActivationTemp maxAbsorption rateCapacity
HR1 SeriesPd metal foil (0.002" / 0.004")No500°C (operating)455 ppm/in²/min (H₂)20 cc/cc (H₂)
HGI SeriesDispensed/printed on lid/coupon4hrs at 100°C120°C (processing)
HTI SeriesDispensed/printed on lid/coupon4hrs at 100°C320°C (processing)
HTA SeriesTabletOptional (pre-activated)400°C (effective)
CP SeriesTabletRequired (normally)500°C (processing/storage)
CP Vacuum SeriesTabletActivate during pump down (250°C)NS